Gen4 ​Enclosures

The E-Series enclosures provide a simple, flexible way to test up to twelve U.2, U.3, or EDSFF 1U SSDs when connected to an OakGate expandable desktop or 3U rackmount appliance. The Enduro/SVF Pro software, supplied with the appliance, can exercise each SSD individually, as well as provide built-in power cycling and power measurement capabilities.

12-Bay Enclosures

To maintain the OakGate hardware warranty, some restrictions apply, as defined in the OakGate Product Warranty Notice.


  • U.2 Enclosures (PCIe Gen4)

    12-Bay U.2 Enclosure for PCIe Gen4

    (OGT-EU12P-01-G4, OGT-EU12P-02-G4, OGT-EU12S-01-G4)

    When connected to an OakGate expandable desktop or 3U rackmount appliance, the E-Series 12-Bay U.2 Enclosure for PCIe Gen4 allows testing for up to twelve NVMe or SAS/SATA solid state drives (SSDs) that use a U.2/SFF-8639 connector. The OakGate Enduro controller application and Storage Validation Framework Pro (SVF Pro) software, supplied with the appliance, can exercise each SSD individually, as well as provide built-in power cycling and power measurement capabilities.

    12-Bay U.2 Enclosure

      E-Series 12-Bay U.2 Enclosure for PCIe Gen4 Product Brochure

    U.2 Enclosure Features & Specifications

    • PCI Express® 4.0 (PCIe Gen4) compatible
    • Supported protocols include: NVMe, NVMe-MI (standard and basic), SAS, SATA, AHCI
    • Supported U.2 SSDs include: single/dual-port NVMe, single/dual-port 12G SAS, and single-port 6G SATA
    • Ability to run unique tests on each device individually and concurrently
    • LED indicators: power (green) and activity (amber) on front of enclosure
    • Simple, tool-less device replacement
    • Rack-mountable using the included rack-rail kit

    • Individual power cycling and power measurement under software control:
      • Configurable to support 3.3V, 5V, and 12V
      • Ability to turn power on/off to each port/device
      • Ability to measure voltage and current for each port/device (at a sample rate of approximately one read/second)
      • Ability to measure power under various low power states (at a sample rate of approximately one read/second)
    • Dimensions: 19" rackmount enclosure with chassis dimensions of 17.5" W × 5.25” (3U) × 20" D
    • Power supply of 850W
    • Maximum drive power is 40W/drive


    U.2 Enclosure Types

    To accommodate a variety of testing needs, three types of the enclosure are available:

    12-Bay Single-Port NVMe U.2 Enclosure for PCIe Gen4
    (OGT-EU12P-01-G4)

    Accommodates up to 12 single-port NVMe U.2 SSDs.

    Supported with an expandable desktop or a 3U rackmount appliance.

    Includes:

    • 12 device carriers
    • External HIB, installed in the appliance
    • External SFF-8644 (4 connectors) to SFF8644 (4 connectors) cable for NVMe SSD connections
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    12-Bay Dual-Port NVMe U.2 Enclosure for PCIe Gen4
    (OGT-EU12P-02-G4)

    Accommodates up to 12 single/dual-port NVMe U.2 SSDs.

    Supported with a 3U rackmount appliance only.

    Includes:

    • 12 device carriers
    • Two external HIBs, installed in the appliance
    • Two external SFF-8644 (4 connectors) to SFF8644 (4 connectors) cable for dual-port NVMe SSD connections
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    12-Bay SAS/SATA U.2 Enclosure
    (OGT-EU12S-01-G4)

    Accommodates up to 12 single/dual-port 12G SAS and single-port 6G SATA U.2 SSDs.

    Supported with an expandable desktop or a 3U rackmount appliance.

    Includes:

    • 12 device carriers
    • Three SAS/SATA HBAs, installed in the appliance
    • Six external HD mini-SAS SFF-8644 cables for SAS/SATA SSD connections
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support

    U.2 Enclosure Ordering Information

    The following table lists the available 12-Bay U.2 enclosures for PCIe Gen4, as well as their compatible OakGate appliances and add-ons.

    E-SERIES 12-BAY U.2 ENCLOSURES for PCIE GEN4
    12-Bay Single-Port NVMe U.2 Enclosure for PCIe Gen4 OGT-EU12P-01-G4 get_quote.png
    12-Bay Dual-Port NVMe U.2 Enclosure for PCIe Gen4 OGT-EU12P-02-G4 get_quote.png
    12-Bay SAS/SATA U.2 Enclosure OGT-EU12S-01-G4 get_quote.png
    COMPATIBLE D-SERIES and R-SERIES APPLIANCES
    Expandable Desktop Appliance for PCIe Gen4 OGT-DE200-G4 get_quote.png
    3U Rackmount Appliance for PCIe Gen4 OGT-R300-G4 get_quote.png
    COMPATIBLE A-SERIES ADD-ONS
    PCIe Power Interposer Card for some appliances and enclosures OGT-AP100 get_quote.png
  • U.3 Enclosures (PCIe Gen4)

    12-Bay U.3 Enclosure for PCIe Gen4

    (OGT-EU3-12P-01-G4, OGT-EU3-12P-02-G4)

    When connected to an OakGate expandable desktop or 3U rackmount appliance, the E-Series 12-Bay U.3 Enclosure for PCIe Gen4 allows testing for up to twelve NVMe solid state drives (SSDs) that use a U.3 (SFF-TA-1001) connector. The OakGate Enduro controller application and Storage Validation Framework Pro (SVF Pro) software, supplied with the appliance, can exercise each SSD individually, as well as provide built-in power cycling and power measurement capabilities.

    12-Bay U.3 Enclosure

      E-Series 12-Bay U.3 Enclosure for PCIe Gen4 Product Brochure

    U.3 Enclosure Features & Specifications

    • PCI Express® 4.0 (PCIe Gen4) compatible
    • Supported protocols include: NVMe, NVMe-MI (standard and basic)
    • Supports single/dual-port NVMe SSDs that use a U.3 (SFF-TA-1001) connector
    • Ability to run unique tests on each device individually and concurrently
    • LED indicators: power (green) and activity (amber) on front of enclosure
    • Simple, tool-less device replacement
    • Rack-mountable using the included rack-rail kit

    • Individual power cycling and power measurement under software control:
      • Configurable to support 3.3V, 5V, and 12V
      • Ability to turn power on/off to each port/device
      • Ability to measure voltage and current for each port/device (at a sample rate of approximately one read/second)
      • Ability to measure power under various low power states (at a sample rate of approximately one read/second)
    • Dimensions: 19" rackmount enclosure with chassis dimensions of 17.5" W × 5.25” (3U) × 20" D
    • Power supply of 850W
    • Maximum drive power is 40W/drive


    U.3 Enclosure Types

    To accommodate a variety of testing needs, three types of the enclosure are available:

    12-Bay Single-Port NVMe U.3 Enclosure for PCIe Gen4
    (OGT-EU3-12P-01-G4)

    Accommodates up to 12 single-port NVMe U.3 SSDs.

    Includes:

    • 12 device carriers
    • External HIB, installed in the appliance
    • External SFF-8644 (4 connectors) to SFF-8644 (4 connectors) cable for NVMe SSD connections
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    12-Bay Dual-Port NVMe U.3 Enclosure for PCIe Gen4
    (OGT-EU3-12P-02-G4)

    Accommodates up to 12 single/dual-port NVMe U.3 SSDs.

    Includes:

    • 12 device carriers
    • Two external HIBs, installed in the appliance
    • Two external SFF-8644 (4 connectors) to SFF-8644 (4 connectors) cable for dual-port NVMe SSD connections
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support

    U.3 Enclosure Ordering Information

    The following table lists the available 12-Bay U.3 enclosures for PCIe Gen4, as well as their compatible OakGate appliances, modules, and add-ons.

    E-SERIES 12-BAY U.3 ENCLOSURES for PCIE GEN4
    12-Bay Single-Port NVMe U.3 Enclosure for PCIe Gen4 OGT-EU3-12P-01-G4 get_quote.png
    12-Bay Dual-Port NVMe U.3 Enclosure for PCIe Gen4 OGT-EU3-12P-02-G4 get_quote.png
    COMPATIBLE D-SERIES and R-SERIES APPLIANCES
    Expandable Desktop Appliance for PCIe Gen4 OGT-DE200-G4 get_quote.png
    3U Rackmount Appliance for PCIe Gen4 OGT-R300-G4 get_quote.png
    COMPATIBLE A-SERIES ADD-ONS
    PCIe Power Interposer Card for some appliances and enclosures OGT-AP100 get_quote.png
  • EDSFF Enclosures (PCIe Gen4)

    12-Bay EDSFF Enclosures for PCIe Gen4

    (OGT-EDL12P-01-G4, OGT-EDL12P-02-G4, OGT-EDS12P-01-G4, OGT-EDS12P-02-G4)

    When connected to an OakGate expandable desktop or 3U rackmount appliance, the E-Series 12-Bay EDSFF Enclosure for PCIe Gen4 allows testing for up to twelve Enterprise and Datacenter SSD Form Factor (EDSFF) 1U NVMe solid state drives (SSDs) that use a x4 (1C) SFF-TA-1002 connector. The EDSFF enclosures supports testing for 1U Long and 1U Short SSDs:

    • PCIe Gen4 12-Bay Enclosure for EDSFF 1U Long NVMe SSDs:
      • OGT-EDL12P-01-G4: single-port
      • OGT-EDL12P-02-G4: dual-port
    12-Bay U.2 Enclosure

    • PCIe Gen4 12-Bay Enclosure for EDSFF 1U Short NVMe SSDs:
      • OGT-EDS12P-01-G4: single-port
      • OGT-EDS12P-02-G4: dual-port
    12-Bay U.2 Enclosure


    The OakGate Enduro controller application and Storage Validation Framework Pro (SVF Pro) software, supplied with the appliance, can exercise each SSD individually, as well as provide built-in power cycling and power measurement capabilities. The front panel of this 3U enclosure provides access to the device slots, as well as the slot's activity and power LEDs.

    12-Bay EDSFF Enclosures Features & Specifications

    • PCIe Gen4 compatible
    • Contain 12 bays, each with a x4 (1C) SFF-TA-1002 connector
    • Tests EDSFF 1U NVMe SSDs
    • Ability to run unique tests on each SSD individually and concurrently
    • LED indicators on front of enclosure:
      • Power (green)
      • Activity (amber)
    • Simple, tool-less device replacement

    • Individual power cycling and power measurement under software control:
      • Configurable to support 3.3V, 5V, and 12V
      • Ability to turn power on/off to each port/device
      • Ability to measure voltage and current for each port/device (at a sample rate of approximately one read per second)
      • Ability to measure power under various low power states (at a sample rate of approximately one read per second)
    • Rack-mountable using the included rack-rail kit


    12-Bay EDSFF Enclosure Types

    Depending on the EDSFF type (1U Long or 1U Short) and whether the NVMe SSD is single-port or dual-port, four types of the 12-bay EDSFF Enclosure are available.

    PCIe Gen4 12-Bay Enclosure for Single-Port EDSFF 1U Long NVMe SSDs
    (OGT-EDL12P-01-G4)

    Tests up to 12 EDSFF 1U long, single-port NVMe SSDs

    Supported with an expandable desktop or a 3U rackmount appliance.

    Includes:

    • NVMe x16 host card (installed in appliance)
    • iPass/SFF-8644 (x4) cable
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    PCIe Gen4 12-Bay Enclosure for Dual-Port EDSFF 1U Long NVMe SSDs
    (OGT-EDL12P-02-G4)

    Tests up to 12 EDSFF 1U long, dual-port NVMe SSDs

    Supported with 3U rackmount appliance only.

    Includes:

    • Two NVMe x16 host card (installed in appliance)
    • Two iPass/SFF-8644 (x4) cable
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    PCIe Gen4 12-Bay Enclosure for Single-Port EDSFF 1U Short NVMe SSDs
    (OGT-EDS12P-01-G4)

    Tests up to 12 EDSFF 1U short, single-port NVMe SSDs

    Supported with an expandable desktop or a 3U rackmount appliance.

    Includes:

    • NVMe x16 host card (installed in appliance)
    • iPass/SFF-8644 (x4) cable
    • 12 device carriers
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support
    PCIe Gen4 12-Bay Enclosure for Dual-Port EDSFF 1U Short NVMe SSDs
    (OGT-EDS12P-02-G4)

    Tests up to 12 EDSFF 1U short, dual​​-port NVMe SSDs

    Supported with 3U rackmount appliance only.

    Includes:

    • Two NVMe x16 host card (installed in appliance)
    • Two iPass/SFF-8644 (x4) cable
    • 12 device carriers
    • USB cable
    • Power cord
    • Rack-rail kit
    • One-year hardware/software support

    12-Bay EDSFF Enclosure Ordering Information

    The following table lists the available 12-Bay EDSFF enclosures, as well as their compatible OakGate appliances.

    E-SERIES 12-BAY EDSFF ENCLOSURES for PCIE GEN4
    PCIe Gen4 12-Bay Enclosure for EDSFF 1U Long Single-port NVMe SSDs OGT-EDL12P-01-G4 get_quote.png
    PCIe Gen4 12-Bay Enclosure for EDSFF 1U Long Dual-port NVMe SSDs OGT-EDL12P-02-G4 get_quote.png
    PCIe Gen4 12-Bay Enclosure for EDSFF 1U Short Single-port NVMe SSDs OGT-EDS12P-01-G4 get_quote.png
    PCIe Gen4 12-Bay Enclosure for EDSFF 1U Short Dual-port NVMe SSDs OGT-EDS12P-02-G4 get_quote.png
    COMPATIBLE D-SERIES and R-SERIES APPLIANCES
    Expandable Desktop Appliance for PCIe Gen4 (N/A for 12-bay dual-port NVMe EDSFF enclosures) OGT-DE200-G4 get_quote.png
    3U Rackmount Appliance for PCIe Gen4 OGT-R300-G4 get_quote.png
​​